SE |
On |
|
Forces drive to use single-ended I/O drivers/receivers only. |
Off |
|
Drive can operate on the interface in low voltage differential mode or single-ended, depending on the voltage state of the I/O “DIFFSNS” line. Default is SE jumper not installed. |
DS |
ME |
Off |
Off |
Spindle starts immediately after power up - Default setting. |
Off |
On |
Drive spindle does not start until Start Unit command received from host. |
On |
Off |
Spindle Startup is delayed by SCSI ID times 12 seconds after power is applied, i.e., drive 0 spindle starts immediately when DC power connected, drive 1 starts after 12 second delay, drive 2 starts after 24 second delay, etc. |
On |
On |
Drive spindle starts when Start Unit command received from host. Delayed start feature is overridden and does not apply when ME jumper is installed. |
WP |
On |
|
Entire drive is write protected. |
Off |
|
Drive is not write protected. Default is WP jumper not installed. |
PD |
On |
|
Parity checking and parity error reporting by the drive is disabled. |
Off |
|
Drive checks for parity and reports result of parity checking to host. Default is PD jumper not installed. |
RES |
Off |
|
Reserved jumper position. Default is no RES jumper installed. |
TP1 |
Off |
|
The drive does not supply terminator power to external terminators or to the SCSI bus I/O cable. |
On |
|
Drive supplies power to SCSI bus I/O cable. When drives have differential I/O circuits, a jumper on the TP1 position may be needed to power external terminators. These drives do not have terminator circuits on the drive. |