SCSI devices not detected in the full dock running WFW 3.11

ISSUE:When running Windows for Workgroups 3.11 on a Gateway Solo 2300 or Solo 9100, using a Full Dock (DCKEXP001AAWW, 8001422, 8001562 ) with SCSI devices, problems may arise trying to get the SCSI devices to detect.

RESOLUTION:There has been a change in the EMM386 line. Please change the EMM386 line to read:

DEVICE=C:\DOS\EMM386.EXE NOEMS I=B000-B7FF X=D000-DBFF.

Note: Any additional settings added to this line may cause the SCSI devices to not be recognized.

The Faxable document number for this page is: 0349. More information on how to use the Faxable service is available through the Gateway Web site.



   